Instructions for
M
-
3, M
-
5, M
-
12 & M
-
16 M-Series
13655 Stowe Dr., Poway, Ca. 92064
Model #
Serial #
Form # ADM-MSeries
1-12
M-3 p. 2
M-5 p. 8
M-12 p. 14
M-16 p. 21
General information p. 27
Please read before use.
Register your product
at www.mytee.com/help
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Instructions for

Instructions for M-3, M-5, M-12 & M-16 M-Series™13655 Stowe Dr., Poway, Ca. 92064Model # Serial # Form # ADM-MSeries 1-12M-3 p. 2 M-5 p. 8 M-12 p.

Page 2

9M-5 SWITCHES & PRESSURE GAUGESwitches and Pressure Gauge are located on the plate in front of the machine. The Amber light left of the Pressure G

Page 3 - 3 M-SERIES™

10M-5 FILTER MAINTENANCECLEAN WATER INTAKE FILTERPUMP-OUT FILTERPRIME VALVE FILTERTo clean the internal lters, lift solution lid and/or remove recove

Page 4

11M-5 M-SERIES™ PARTS & PRICINGPart prices are subject to change.Order parts at: http://www.mytee.com/products/product.php?id=M-5ITEMS NOT SHOWNAC

Page 5

12M-5 PARTS & PRICING1234578910 121314151617181922122232425266271128293029313232333435363437313839404111584243124546484947344505153545556115741415

Page 6

13DCBAABCD1234567887654321EFEFM5SHEET 1 OF 1M SeriesSCALE: 1:2REVDWG. NO.DSIZETITLE:NAMEDATECHECKEDDRAWNPROPRIETARY AND CONFIDENTIALTHE INFORMATION C

Page 7 - M. LaBarbera

14M-12 BACKM-12 FRONT1. Switch plate2. 2” Male Cuff-Lynx™ 3. Female quick disconnect (QD) 4. Front handles 5. Prime valve 16. Pressure regulator 7.

Page 8 - M3Wiring

15Switches and Pressure Gauge are located on the plate in front of the machine. The Amber light left of the Pressure Gauge will illuminate when cords

Page 9

16Press right side of Pump mode button for Tile. The Amber light left of the Pressure Gauge will illuminate when cords are plugged into two separate c

Page 10 - 5 M-SERIES™

17M-12 FILTER MAINTENANCETo clean the internal lters, lift solution lid and/or remove recovery tank lid, reach in and twist off. Rinse with clean wat

Page 11

18M-12 PARTS & PRICINGPart prices are subject to change.Order parts at: http://www.mytee.com/products/product.php?id=M-12ITEMS NOT SHOWNACCESSORIE

Page 13 - 5 PARTS & PRICING

19M-12 PARTS & PRICING1234567821617718151011121314192122232425262729303132334343939403841428353637924344562245464715484950515253545532333268293032

Page 14 - 5 WIRING DIAGRAM

20M-12 WIRING DIAGRAMAABBCCDDEE1 12 23 34 4Pump1200PumpOutPump200WhiteBlackBlackWhiteGreenRedGreenGreenWhiteWhiteBlueGreenWhiteBlueBrownRedBlackBlackY

Page 15 - Bottom cord

21M-16 DUAL CORDSPlug each of the two power cords into two separate, 20A grounded wall outlets. The amber light indicator on the switch plate will ill

Page 16 - M-12 CARPET MODE

22Switches and Pressure Gauge are located on the plate in front of the machine. The Amber light left of the Pressure Gauge will il-luminate when cords

Page 17 - M-12 FILL SOLUTION TANK

23M-16 DRAIN VALVE & LATCHESYou can drain the recovery tank by using the Drain Valve. When not using the Auto Pump-out, you can drain the recovery

Page 18 - M-12 AUTO-FILL & FLOAT

24M-16 PARTS & PRICINGPart prices are subject to change.Order parts at: http://www.mytee.com/products/product.php?id=M-16ITEMS NOT SHOWNPART NODES

Page 19 - 12 PARTS & PRICING

25M-16 PARTS & PRICING123568791112131415161718212022 2324262527282930313233342411353637403831414243104544 464748496505152754555439 565253585960395

Page 20

26M-16 WIRING DIAGRAMDCBAABCD1234567887654321EFEFM16SHEET 1 OF 1M SeriesSCALE: 1:2REVDWG. NO.DSIZETITLE:NAMEDATECHECKEDDRAWNPROPRIETARY AND CONFIDENT

Page 21 - M12WiringDiagram

27Dear Customer: Congratulations on the purchase of your new M-Series™ Extractor. As you are already aware, the scene of the equipment world is becomi

Page 22

285. Attach one end of the vacuum hose from a wand or other attachment to the front Cuff-Lynx™ vacuum hose port. 6. Plug in power cords. • M-3 – Plug

Page 23 - M-16 VAC/SOL HOSE CONNECTIONS

2M-3 BACKM-3 FRONT1. Switch plate2. 2” Male Cuff-Lynx™ 3. Female quick disconnect (QD) 4. Front handles 5. Prime valve 16. Pressure regulator 7. Fron

Page 24 - M-16 AUTO-FILL & FLOAT

29Q: Where do I plug the machine in? A: Into two separate 20A grounded circuits. Q: How will I know when I nd two separate circuits?A: The amber ind

Page 26

Mytee Products Inc. 13655 Stowe Dr. Poway, Ca. 92064 www.mytee.comPH 858.679.1191 F X 858.679.7814 © 2012 Mytee Products Inc.Printed in the U.S.A.

Page 27 - Top Cord

3M-3 SWITCHES & PRESSURE GAUGESwitches and Pressure Gauge are located on the plate in front of the machine. The Amber light left of the Pressure G

Page 28 - General information

4M-3 DRAIN VALVE & LATCHESYou can drain the recovery tank by using the Drain Valve. When not using the Auto Pump-out, you can drain the recovery t

Page 29 - General Information

5M-3 M-SERIES™ PARTS & PRICINGPart prices are subject to change.Order parts at: http://www.mytee.com/products/product.php?id=M-3ITEMS NOT SHOWNITE

Page 30

6M-3 M-SERIES™ PARTS & PRICING58596058575567226853697025257576868348666565909694808078182518 83178381899091809253531145141506511865119 23989754100

Page 31

7M3AmberM3WiringPUMPOUTTopCordBottomCordM-3 M-SERIES™ WIRING DIAGRAM

Page 32

8M-5 DUAL CORDSPlug each of the two power cords into two separate, 20A grounded wall outlets. The amber light indicator on the switch plate will illum